dc.description.abstractConcrete is a poor conductor of heat, but can suffer considerable damage when exposed to fire. Concrete in structures is likely to be exposed to high temperatures during fire. The relative properties of concrete after such an exposure are of great importance in terms of the serviceability of buildings. Unraveling the heating history of concrete is important to forensic research or to determine whether a fire exposed concrete structures and its components are still structurally sound or not. Assessment of fire damage concrete structures usually starts with visual observation of color change, cracking and spalling. On heating, a change in color from normal to pink is often observed and this is useful since it coincides with the onset of significant loss of concrete strength. This work reports the characteristics of concrete at elevated temperatures. Popular normal strength grades (M20, M25, M30, M35, M40 and M45) produced by Ready Mix Concrete (RMC) India, Mangalore have been used in production of test specimens (150 mm diameter and 300mm height cylinders) to obtain more meaningful and realistic data. In the preliminary phase 150 mm diameter and 300mm height cylinders were cast, cured and tested by destructive method for gathering data on strength characteristics. Later these test samples were subjected to elevated temperatures ranging from 100 C to 800 C, in steps of 100 C with a retention period of 2 hours. After exposure, weight losses were determined and then again destructive tests were conducted to estimate the residual split tensile strength. Test results indicated that weight and strength significantly reduces with an increase in temperature. 2010 CAFET-INNOVA TECHNICAL SOCIETY. All rights reserved.en_US
dc.titleStudies on concrete cylinders subjected to elevated temperaturesen_US