dc.description.abstract | The incorporation of the abundantly available wind and solar energy to the grid using power electronic converter based interfaces makes a reliable hybrid renewable energy system. Assigning harmonic mitigation property to the grid interfacing inverter to mitigate the current harmonics created by the non-linear loads at the load centres, is a cost-effective solution. The inverter controller consists of an outer DC-link voltage control loop and an inner current harmonic mitigation loop. The limitations of existing DC-link voltage controllers are poor stability margin, steady-state error and chattering problem. The widely used pq theory based inner loop controller offers poor performance under non-ideal grid voltage conditions. The conventional low pass filter based fundamental component extraction methods used in pq theory possess some limitations such as additional time delays and low-frequency oscillations. The main focus of this research is the design, simulation, implementation and analysis of a grid-tied wind-solar hybrid renewable energy system with shunt and series active filtering functionalities, under different system conditions. A Backstepping controller based outer loop, with enhanced DC-link loss compensation capability is proposed for the shunt active filter to overcome the limitations of the existing DC-link voltage controllers. The limitations of conventional low pass filter based fundamental component extraction methods are overcome by employing a self-tuning filter in the inner loop of the shunt active filter. An additional self-tuning filter is incorporated to improve the effectiveness of pq theory under non-ideal grid conditions. A self-tuning filter and a Fuzzy logic-based voltage controller are employed to control the series active filter effectively. A laboratory prototype of the shunt active power filter is implemented. The control algorithm is realised in Xilinx Basys-3 FPGA. From the simulation and hardware test results under steady-state and dynamic conditions, it is found that the proposed controller offers better stability, robustness and speed compared to other existing control methods. | en_US |
dc.language.iso | en | en_US |
dc.publisher | National Institute of Technology Karnataka, Surathkal | en_US |
dc.subject | Department of Electrical and Electronics Engineering | en_US |
dc.subject | Power quality | en_US |
dc.subject | Active power filter | en_US |
dc.subject | Grid-tied renewable system | en_US |
dc.subject | Back stepping Control | en_US |
dc.subject | Dual Self Tuning Filter | en_US |
dc.subject | Fuzzy logic | en_US |
dc.subject | DC-link voltage control | en_US |
dc.title | Grid Connection of Wind-Solar Hybrid Renewable Energy System, with Active Power Filter Functionality | en_US |
dc.type | Thesis | en_US |