Please use this identifier to cite or link to this item: http://idr.nitk.ac.in/jspui/handle/123456789/14680
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKariganaur A.K.
dc.contributor.authorKumar H.
dc.contributor.authorMahalingam A.
dc.date.accessioned2021-05-05T10:15:39Z-
dc.date.available2021-05-05T10:15:39Z-
dc.date.issued2020
dc.identifier.citationJournal of Physics: Conference Series , Vol. 1706 , 1 , p. -en_US
dc.identifier.urihttps://doi.org/10.1088/1742-6596/1706/1/012193
dc.identifier.urihttp://idr.nitk.ac.in/jspui/handle/123456789/14680-
dc.description.abstractMagnetorheological damper is vibration reducing system in which the magnetorheological fluid is the operating liquid which changes its behaviour with external stimulus by increasing the yield stress of fluid with the application of external magnetic field. Most of the vibration reducing equipment's is operated with single coil, and in this paper, study of multi coil magnetorheological damper is discussed and compared with the single coil for its magnetic flux density of the applied currents is studied by dividing equal and unequal number of turns of the coil in multi coil unlike in single coil damper. © Published under licence by IOP Publishing Ltd.en_US
dc.titleComparative study on the effect of single coil and multi coil magnetorheological damper through finite element analysisen_US
dc.typeConference Paperen_US
Appears in Collections:2. Conference Papers

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.